How Does Stenter Maintain Equipment

    1. Check the equipment circuit for damage and safety hazards!

      2. The squeegee lifts the round rod, the off-net screw rod, the lift screw, and the frequent moving parts frequently add butter and regular maintenance!

      3. Stenter internally checks for broken glass slag and cleans it up in time!
       
      4. The equipment gas storage tank should be drained regularly to keep the pipeline clean and free of impurities. The working pressure of the equipment is 5.5-6 MPa!
       
      5. Please add butter for maintenance of transmission parts, such as bearings and chains!
       
      6. Keep the equipment clean and hygienic. If there is ink, please wipe it with alcohol!
       
      7. Check the gas path, whether there is air leakage, whether there is abrasion, and replace it in time!
       
      8. The Flat Screen Printing Machine Factory reminds you that the cold weather in the north, please add refrigerating oil to the reducer to keep the parts lubricated and smooth!